SEER2 Energy Savings Estimator
Compare two hypothetical efficiency ratings using your system size, cooling hours and electricity rate.
Current
—
—
New
—
—
Estimated annual cooling savings
—
— less cooling energy · about — over 10 years at today's rate
Estimates only. Actual savings depend on installation quality, ductwork, thermostat settings, weather, humidity and rate changes. These figures are not a guarantee.
Assumptions
- Annual cooling energy (kWh) = system capacity (BTU/h) × full-load cooling hours ÷ (SEER2 × 1,000).
- "Full-load hours" are the equivalent hours the system would run at full capacity over a season. Actual run time is longer because systems often run at partial load.
- Both systems are assumed to be the same capacity and correctly sized.
- The 10-year figure multiplies annual savings by ten with no change in electricity rates or efficiency and no discounting.
- Older systems are often rated in SEER rather than SEER2. SEER2 values are lower for the same equipment because of the updated DOE test procedure, so converting an old SEER rating requires care. For example, the 2023 federal minimum of 15 SEER in the South corresponds to 14.3 SEER2.
- Heating energy for heat pumps (rated in HSPF2) is not included.